 | Current Limiting fuses Class CC & Holders Rejection tips on the bottoms to prevent them from being used in holders not rated similarly. Branch circuit rated for 600 VAC (EDCC also 300 VDC), 0.5-30 Amps, Interrupt Rated: 200,000 RMS Symmetrical Amps, UL, CSA, CE
- HCLR Series - Fast-acting design responds quickly to both overload and short-circuit current, ideal for resistive heating and lighting loads.
- HCTR Series - Time-delay design allows closer sizing for inductive loads such as control transformers and solenoids
- EDCC Series - Time-delay design specifically designed for motor protection, provides excellent current limiting capabilities. Use for protection of small horsepower motor circuits or other circuits requiring small dimension, time-delay fuses.
|
| |
 | Current Limiting High-Speed Class J Drive Fuses JHL series class J fuses combine the performance of high-speed semiconductor fuses and the convenience of Class J branch-circuit fuses in one small package, allowing maximum protection for AC and DC drives and controllers.
JHL series high-speed fuses can be used with GS and DURAPULSE drives in non-UL applications. Fuse the drive according to NEC guidelines (NEC Article 430).
For UL applications, GS and DURAPULSE drives require Class T fuses (refer to the drives user manual for details).
|
| |
 | Current Limiting Class T Fuses & Holders TJN and TJS Class T fuses are extremely fast-acting industrial fuses in a compact, space-saving size. These Edison fuses are ideal as the main fuse protection for panel boards, load centers, meter stacks, and AC drives. These type T fuses are also referred to as fast blow fuses or high speed fuses.
Class TJN: 300 VAC, 1-200 Amp, 225-600 Amp Class TJS: 600 VAC, 1-200 Amp, 225-600 Amp |
| |
 | Current Limiting Class J Fuses & Holders Recommended for Type 2 (no damage) protection of IEC style motor starters and contactors, and to protect lower interrupting rated circuit breakers. All general purpose circuits with inductive (high inrush) loads, including motor and motor branch circuits, transformer circuits and lighting loads. Rated for 600 VAC, 1 - 600 Amps, Interrupt Rated: 200,000 (Self-Certified to 300,000) RMS Symmetrical Amps, UL, CSA
- Space saving dimensions compared to Class R fuses
- Dual-Element construction provides superior time-delay to pass harmless motor or transformer surges
|
| |
 | Current Limiting Class RK5 Fuses & Holders Popular fuses and economical fuses for most applications, especially motors and transformers. Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads (motors, transformers) or non-inductive loads (lighting, heating) where the available short-circuit current does not exceed 200,000 RMS symmetrical amperes. These true dual element, time-delay fuses have minimum industry standard time-delay of 10 seconds at 5 times the fuse rating (8 sec. minimum for 250V, 30A and less). The time-delay characteristics of these fuses allows them to be sized closer to the running current of inductive loads to reduce cost and provide tight overcurrent protection. UL, CSA ECNR Series - 250 VAC rated, 1 - 600 amps ----- ECSR Series - 600 VAC rated, 3 - 600 amps |
| |
 | Current Limiting Class RK1 Fuses & Holders Up to 40% more current limitation and up to 350% more Amps-Squared-Second (I2t) limitation under fault conditions than ECNR/ECSR series fuses, reducing the potential for damage. They also offer a better selection for electrical power system designers and superior short circuit protection for breakers having inadequate interrupting ratings. ECNR/ECSR and LENRK/LESRK fuse lines are interchangeable. UL, CSA. KENRK Series - 250 VAC rated, 10 - 600 amps ----- LESRK Series - 600 VAC rated, 5 - 600 amps |
| |
 | General Purpose - Class M (Midget) Fuses & Holders For supplemental fuse protection of non-inductive control circuits, street lighting holders, HID lighting and electronic equipment that require high interrupt ratings and fast-acting response. UL, CSA, CE. MCL Series - 600 VAC rated, 0.5 - 50 amps ----- MOL Series - 250 VAC rated, 0.5 - 50 amps For supplemental protection of small motors, transformers, solenoids, and other high-inrush power electronic circuits that requre a time-delay response to prevent nusance tripping. UL, CSA, CE. MEQ Series - 500 VAC rated, 0.25 - 30 amps ----- MEN Series - 250 VAC rated, 0.5 - 30 amps |
| |
 | Small Dimension Electronic Glass Fuses A group of low voltage glass body general purpose fuses. used to protect electronic circuits and components. AGC Series - 1/4” x 1-1/4” Fast-Acting fuses --------------------- MDL Series - 1/4” x 1-1/4” Time-Delay fuses GMA Series - 5x20 mm Fast-Acting fuses ------------------------ GMC Series - 5x20 mm Medium Time-Delay fuses S500 Series - 5x20 mm Fast-Acting, RoHS compliant fuses ---- S506 Series - 5x20 mm Time-Delay RoHS compliant fuses |
| |
 | Small Dimension Electronic Ceramic Fuses A group of low voltage ceramic body general purpose fuses. used to protect electronic circuits and components.
- ABC Series - 1/4” x 1-1/4” Fast-Acting fuses
- MDA Series - 1/4” x 1-1/4” Time-Delay fuses
|
| |
 | PLC Spare Fuses Spare fuses available for the DirectLOGIC DL205, DL305, DL405 Programmable Logic Controller family of products, Terminator I/O series, and ZIPLinks. |
| |
 | GS Drives Fuse Kits & Spare Fuses Fuse kits consist of fuse block(s) and fuses sized to match each GS1, GS2, or DURApulse series AC drive. Replacement fuses are also available. Fuse kits are available to suit 115, 230 or 460 V single-phase or 3-phase input models. |
| |
 | Fuse Holders, Fuse Blocks & Accessories Fuse accessories including fuse holders, fuse blocks, a fuse puller, and assembly pins for assembling 2 and 3-pole CHM or CHCC series fuse holders. UL, CSA, CE. |
| |