DL06 - Great fit for Practical On/Off Control!


 

dl06_practical_on-off.pdf (439kb)

Nine models available
- The DL06 PLC line includes nine models to choose from in both 115/230vAC and 12/24vDC power.
Eight PID loops with auto-tune
The DL06 supports its great analogue capabilities with PID and floating point math at no additional charge.
Thirty-six built-in I/O points
- All nine DL06 models include 20 inputs and 16 outputs for a total of 36 built-in discrete I/O in a variety of AC, DC and relay combinations.
Discrete I/O option modules
allow the DL06 to expand with the needs of your application for very little extra, up to 100 I/O in the same base footprint.
Flexible programming
Our FREE DirectSOFT programming package, PC-DS100,* combined with the powerful DL06 instruction set, makes programming your application simple and affordable.
Easy ZIPLink connection
16-point option modules can connect to a variety of ZIPLink modules, including low-cost feed-through terminals, fuse, LED, and even relay modules.

DL06 - Great fit for Flexible Analogue Control!


 

dl06_analog_control.pdf (460Kb)

Really low prices
Combine a 4-channel analogue input module with our DL05 PLC for low-cost analogue monitoring. Use the built-in PID loops and build a micro control system at an unbeatable price.
Eight PID loops with auto-tune
The DL06 supports its great analogue capabilities with PID and floating point math at no additional charge.
C-more panels
offer a low-cost window into your application. Our C-more panels have some of the best features in the market for process HMI applications.
Powerful communications
- built-in and expansion. Combine a DL06 AC or DC-powered unit with our industrial telephone modem and avoid the high cost of an advanced Remote Telemetry System (RTU).
Direct wiring
with the analogue option modules to most common analogue devices such as pressure and level transmitters, proportional valves, AC drives, panel meters, etc.
Thirteen Analogue modules
to choose from including 4-20 mA or 0-20 mA, and 0-5V or 0-10V input and output ranges. Six New fast 16-bit modules. DL06 analogue modules are the smallest and lowest-priced in the industry.

DL06 - Great Fit for Communication-Enabled Applications!


 

dl06_analog_control.pdf (457kb)

Flexible communications
- The most flexible ports in its class. The DL06 has two built-in communication ports. Port 2 has the same communication capabilities as many larger PLCs.
Ethernet connectivity
DL05/ 06 H0-ECOM Ethernet Modules provide a 10 Mbit or 100 Mbit Ethernet link for peer-to-peer PLC communications and for data serving to HMI/SCADA systems using OPC over Ethernet.
Connect directly to ASCII devices
The DL06 allows you to easily perform ASCII operations at no additional charge!
ASCII and Modbus
fill-in-the-blanks instructions. The DL06 includes easy-to-use communication instructions for Modbus and ASCII operations.
Versatile programming port
can also be used for operator interface. After programming is complete, use this port to connect to a C-more panel for a low cost HMI solution.

Other Great DL06 Functions and Features !!!


High-Speed Counting
and Pulse Output

Snap-in LCD Display

dl05_super_powerful.pdf(188KB)

dl05_super_powerful.pdf (312KB)

(3.25Mb)     (3.15Mb)      (17.1Mb)      (links)


DL06 PLC unitsDL06 PLC units
The DL06 micro PLC line has nine base units to choose from, each has 20 built-in inputs and 16 built-in outputs. The DL06 is a great fit for high voltage, 220-240 VAC applications or remote 12 VDC applications, and everything in between.
  • Nine units: 100-240 VAC or 12-24 VDC powered
  • AC-powered I/O combinations:
  • AC-in/AC-out, AC-in/relay-out, DC-in/AC-out, DC-in/DC-out, and DC-in/relay-out
  • DC-powered I/O combinations: DC-in/DC-out(sink), DC-in/DC-out(source), and DC-in/Relay-out

DL05/06 Discrete I/O option modulesDL05/06 Discrete I/O option modules
Discrete I/O option modules allow the DL05 PLC to expand with the needs of industrial control applications for just a few dollars more.
  • 8-in, 110 VAC
  • 10-in, 12-24 VDC
  • 16-in, 20-28 VDC
  • 10-out & 16-out 12-24 VDC
  • 4 relay outputs, 5-30 VDC or 5-125 VAC
  • 8 relay outputs, 6-27 VDC or 6-240 VAC
  • Combo 4-in 12-24 VDC, 4-out 12-24 VDC
  • Combo 4-in 12-24 VDC, 3 relay outputs
  • 8 point input simulator module


DL05/06 Analogue I/O option modulesDL05/06 Analogue I/O option modules
Using option modules, analogue I/O can be added to the DL05. These analogue modules are among the smallest and lowest-priced in the industry. 16-bit Resolution ... NEW! 16-Bit analogue modules offer higher resolution, higher density (8 channel), and output-only versions.
12-bit resolution
  • 4 analogue inputs: 4-20 or 0-20 mA
  • 4 analogue inputs: 0-5 V or 0-10 V
  • 2 in / 2 out, 0-5 or 0-10 V
  • 4 in / 2 out, 0-20 or 4-20 mA
  • 4 in / 2 out, 0-5 or 0-10 V
Temperature Measurement
  • 4-channel RTD input
  • 4-channel Thermocouple input
16-bit Resolution
  • 8 analog inputs: 4-20 mA or 0-20 mA
  • 8 analogue inputs: 0-5 V or 0-10 V<
  • 8 / 4 analogue outputs, 4-20 mA
  • 8 / 4 analogue outputs, 0-10 V

DL05/06 Communications & NetworkingDL05/06 Communications & Networking
Implement advanced networking solutions for the DL05 with DeviceNet, Ethernet (10 or 100 MBit), and Profibus Modules. The new D0-DCM module supports DirectNet and Modbus (slave) protocols.
  • Data Communications - network interface to DirectNET and Modbus
  • 10 baseT and 10/100 baseT Ethernet
  • DeviceNET slave module
  • Profibus slave communication module
  • RS232C to RS422/ RS485 converters

DL05/06 Speciality modulesDL05/06 Speciality modules
The H0-CTRIO High-Speed Counter I/O module is the affordable, high-performance, high-feature solution for DL06 counting input and pulse output.
  • High-speed Counter I/O Module
  • Triple-port BASIC Coprocessor
  • Input Simulator

Programming software & cablesProgramming software & cables
The new DirectSOFT5 software package offers a host of advanced features for easier PLC programming.
  • Full-featured 32-bit Windows-certified programming for all DirectLOGIC PLCs
  • ALL NEW IBox instructions
  • FREE version allows a maximum of 100 words for programming, editing, and downloading

DL05 / 06 PLC ZipLinksDL05 / 06 PLC ZipLinks
ZIPLinks eliminate the tedious process of wiring programmable logic controller I/O to terminal blocks using half the space, at a fraction of the total cost of terminal blocks
  • ZIPLinks are available for all PLC base units and all discrete input and output modules

DL05/06 Spare parts & AccessoriesDL05/06 Spare parts & Accessories
The optional D0-06LCD is an easy to install cost effective LCD display panel for the DL06.
  • Optional LCD Display (D0-06LCD)
  • Serial communication port adapter
  • Replacement terminal blocks, covers, labels
  • CPU battery, cable kits, RS232C to RS422/ RS485 converters
spacer