Low-Cost Basic Series
|
|
 | Manual Starters & Protectors Contained in one unit is motor overload protection, instantaneous short circuit trip, phase loss protection and ON/ OFF switching with lockout/ tagout capability.
- Push on / push off manual control disconnects power from motor
- Electromagnetic short circuit protection eliminates the need for separate breakers or fuses
- Overload heater strips protect the motor from sustained overload conditions
- Phase loss detection trips as a function of thermal overload when a phase is lost to protect the motor
- Options include undervoltage trip, remote shunt trip, and auxiliary contacts
|
| |
 | Auxiliary Contacts Snap-on top mount in four versions:
- 1 normally open, 1 normally closed contact
- normally open, 2 normally closed contacts
- 3 normally open, 1 normally closed contact
- 4 normally open contacts
- Side mount with 1 normally open/1 normally closed contact
- Contact blocks designed for snap-on installation
|
| |
|
Centsable Contactors/ Starters/ Overloads Electromechanical motor control solutions for motors up to 20 - 300 horsepower at 480 volts. For lower horsepower solutions, choose from the GH Series line of European-made contactors, overloads and motor starter/protectors, or the Cutler-Hammer Freedom series IEC contactors and starters. For higher horsepower solutions, see the Fuji Electric motor control products.
For extreme value in contactors, AutomationDirect offers the GH Series line of load switching devices. These high-quality contactors have the same features as the name brands, but at prices that are hard to beat.
We also have manual starter/ protectors to assemble a super-low cost motor starter with short circuit and overload protection. Our RTD32 and RTD65 adjustable motor overload relays are designed to attach directly to the GH Series 45 mm and 60 mm contactors. By combining a GH Series contactor with a GH Series overload relay, you can have a motor starter solution at a fraction of the cost charged by our competitors. |  |
|
|
|
 | Manual Starters & Protectors Contained in one unit is motor overload protection, instantaneous short circuit trip, phase loss protection and ON/ OFF switching with lockout/ tagout capability.
- Push on / push off manual control disconnects power from motor
- Electromagnetic short circuit protection eliminates the need for separate breakers or fuses
- Overload heater strips protect the motor from sustained overload conditions
- Phase loss detection trips as a function of thermal overload when a phase is lost to protect the motor
- Options include undervoltage trip, remote shunt trip, and auxiliary contacts
|
| |
 | Auxiliary Contacts Snap-on top mount in four versions:
- 1 normally open, 1 normally closed contact
- normally open, 2 normally closed contacts
- 3 normally open, 1 normally closed contact
- 4 normally open contacts
- Side mount with 1 normally open/1 normally closed contact
- Contact blocks designed for snap-on installation
|
| |
|